Brandguard Fire-Resistant Gable Vents

Stopping embers from entering your attic is of paramount importance during ember storms caused by wildfires. With fire-resistant gable vents from Brandguard Vents, you can stay safe, protect your home, and comply with California wildfire protection codes.

Brandguard gable vents feature a patented baffle design to stop embers and prevent the spread of fire.  They’re ideal for use in Wildfire-Urban Interface (WUI) areas.

The vents are aesthetically pleasing and can be painted to match the color of the house. In combination with other Brandguard fire- and ember-resistant vents, you can now protect your home in compliance with Chapter 7A of the California Building Code. 

Custom sizes and shapes are available upon request.

Product Features & Benefits

These unique fire-resistant gable vents:

  • Are available in several standard sizes in both steel and copper.
  • Are proudly manufactured in the USA
  • Can be painted to match your home
  • Are available in round, triangle, and custom shapes and sizes
  • Are available with different installation flange options (see link below)

Request a quote today!

Louvered Vents

People often ask if Brandguard Vents also offers louvered vents. Louvered vents allow airflow while keeping out unwanted elements like rain, debris, and pests. They feature flat strips or angled slats that are hung or fixed at regular intervals. As a traditional vent, they’re a popular choice for doors, shutters, and screens as they allow plenty of air and light to pass through.

Louvers can be static or movable. Because they do not open and close, Brandguard Vents are considered static. The Brandguard gable vents designed with baffles can be defined as “louvered vents” and can also stop embers and fire from entering your home. Additionally, Brandguard gable end louvered vents are ASTM E2886 listed with the State of California State Fire Marshal’s Building Material Listing. If a gable louver vent is not listed here to this highest gold standard, they did meet their required criteria for wildfire ember and fire vents.

Size
Model#
Flange
NFVA (Airflow)
Spec Sheet
12” X 12”h
GV2011-FF
Flange Front
38.6 sq in
Download Spec Sheet
GV2011-PG
Stucco/Plaster/J Channel
38.6 sq in
Download Spec Sheet
GV2011-FB
Flange Back
38.6 sq in
Download Spec Sheet
GV2011-FO
1.5” Setback
38.6 sq in
Download Spec Sheet
12”w x 18”h
GV2021-FF
Flange Front
60.9 sq in
Download Spec Sheet
GV2021-PG
Stucco/Plaster/J Channel
60.9 sq in
Download Spec Sheet
GV2021-FB
Flange Back
60.9 sq in
Download Spec Sheet
GV2021-FO
1.5” Setback
60.9 sq in
Download Spec Sheet
14”w x 18”h
GV2041-FF
Flange Front
71.1 sq in
Download Spec Sheet
GV2041-PG
Stucco/Plaster/J Channel
71.1 sq in
Download Spec Sheet
GV2041-FB
Flange Back
71.1 sq in
Download Spec Sheet
GV2041-FO
1.5” Setback
71.1 sq in
Download Spec Sheet
14”w x 24”h
GV2051-FF
Flange Front
97.6 sq in
Download Spec Sheet
GV2051-PG
Stucco/Plaster/J Channel
97.6 sq in
Download Spec Sheet
GV2051-FB
Flange Back
97.6 sq in
Download Spec Sheet
GV2051-FO
1.5” Setback
97.6 sq in
Download Spec Sheet
18”w x 24”h
GV2071-FF
Flange Front
127 sq in
Download Spec Sheet
GV2071-PG
Stucco/Plaster/J Channel
127 sq in
Download Spec Sheet
GV2071-FB
Flange Back
127 sq in
Download Spec Sheet
GV2071-FO
1.5” Setback
127 sq in
Download Spec Sheet
22”w x 30”h
GV2081-FF
Flange Front
186 sq in
Download Spec Sheet
GV2081-PG
Stucco/Plaster/J Channel
186 sq in
Download Spec Sheet
GV2081-FB
Flange Back
186 sq in
Download Spec Sheet
GV2081-FO
1.5” Setback
186 sq in
Download Spec Sheet
Quote Request

Brandguard fire-resistant gable vents on a California home
California home with Brandguard fire-resistant gable vent
Semi-circle gable vent
Square fire-resistant gable vent
Custom fire-resistant gable vent